Assessment of design suitability and limiting factors of green facade systems in Budapest

Authors

  • Szilvia Weisz Szent István University, Department of Landscape Protection and Reclamation 1118-Budapest, Villányi út 35-43.
  • Zsombor Boromisza Szent István University, Department of Landscape Protection and Reclamation 1118-Budapest, Villányi út 35-43.

DOI:

https://doi.org/10.56617/tl.3521

Keywords:

green infrastructure, living facade, green wall-surface, particulate matter, heat island, landscape architecture

Abstract

During our research the possibilities of establishing living facades - being quite new in Hungary - are investigated by assessing suitability of plots located in Budapest (300 m buffer zone of the measuring stations situated on Erzsébet square, Teleki László square and on Kosztolányi Dezső square). After having defined the suitable facades, it is possible to quantify the impacts, which the green wall surfaces would make on the airquality, as well as on the microclimate. Considering the reasons for exclusion, the plots, being suitable to have living facades are as below: Erzsébet square (15 pcs), Teleki László square (28 pcs), Kosztolányi Dezső square (69 pcs). The assessed plots have 8060,7 m2 potential facades, being, however, not evenly distributed on the various spots. In fact, it is the measuring station on Kosztolányi Dezső square and its 300 m buffer-zone being the most significant ones, representing 54,6% of all suitable wall-surfaces. Having in mind the measured facade surfaces and the vegetated ones, and also on the basis of preliminary researches in this topic it is possible to define the estimated NO2 and PM10 absorption of the vegetation, together with the improving effect of microclimate: the annual absorption of the assessed vegetation amounts to 9,35 tons PM10 and 8 tons NO2, besides reducing the environmental temperature by 3-4 Celsius degrees in the summer period and by 0,7-0,9 Celsius degrees in winter.

Author Biography

  • Szilvia Weisz, Szent István University, Department of Landscape Protection and Reclamation 1118-Budapest, Villányi út 35-43.

    corresponding author
    weisz96@gmail.com

References

Abhijith, K.V., Kumar, P., Gallagher, J., McNabola, A., Baldauf, R., Pillag, F., Broderick, B., Di Sabatino, S., Pulvirenti, B. 2017: Air pollution abatement performances of green infrastructure in open road and built- up Street canyon environments - A review. Atmospheric Environment 162: 71-86. https://doi.org/10.1016/j.atmosenv.2017.05.014

Budapest Környezeti Állapotértékelése 2015, Budapest Főváros Önkormányzata, Budapest.

Budapest Környezeti Programja 2017-2021, Budapest Főváros Ónkormányzata, Budapest.

Csibi K., Dezsényi P., Wien Fári M.G., Koroknai J., Pataky R., Szentkirályi-Tóth F. 2016: Zöldinfrastruktúra füzetek 2. Zöldhomlokzatok Függőleges zöldfelületek tervezésének, kivitelezésének műszaki és kertészeti útmutatója. Budapest Főváros Városépítési Tervező Kft., Budapest, p. 155.

Djedjig, R., Belarbi, R., Bozonnet, E. 2017: Green wall impacts inside and outside buildings: experimental study. Energy Procedia 139: 578—583. https://doi.org/10.1016/j.egypro.2017.11.256

Escobedo, F. J., Kroeger, T., Wagner, J. E. 2011: Urban forests and pollution mitigation: Anayzing ecosystem Services and disservices. Enviromnental Pollution 159(8-9): 2078-2087. https://doi.org/10.1016/j.envpol.2011.01.010

Gábor P., Jombach S. 2008: A zöldfelület intenzitás és a városi hősziget jelenségének összefüggései Budapesten. Falu-Város-Régió 1: 31-36.

Johnston, J., Newton, J. 2004: Building Green. A guide to using plants on roofs, walls and pavements. Greater London Authority, London, p. 121.

Koroknai J., Pataky R., Kaprinyák T., Fári M. G. 2015: Napfényes helyen, HIB modulokban elhelyezett dísznövények nyári vízháztartásának értékelése. Kertgazdaság 47(2): 25—34.

Ljesevic, M. 2002: Urbana Ekologija. Univerzitet u Beogradu Geografski Fakultét, Beograd.

Loksa G. 2004: Meteorológia a tájökológia szolgálatában. Tájökológiai Lapok 2(2): 195-199.

Manson, M. Castro-Gomes, J. 2015: Green wall systems: A review of their characteristics. Renewable and Sustainable Energy Reviews 41: 863-871. https://doi.org/10.1016/j.rser.2014.07.203

Mathey, J., Rößler, S., Wende, W. 2010: Role of urban green spaces for cities under climate change aspects of planning and implementation. UNECE, Prague.

Medl, A., Stangl, R., Florineth, F. 2017: Vertical greening systems - A review on recent technologies and research advancemen. Building and Environment 10: 1016-1054. https://doi.org/10.1016/j.buildenv.2017.08.054

Mezősi G. 2007: Városökológia. JATEPress, Szeged, p. 174.

Mezősné Szilágyi K. 2012: Az „élhető település táj” zöldfelületi, ökológiai, térségi és társadalmi összefüggései. 4D Tájépítészeti és Kertművészeti folyóirat Különszám: 115-124.

Mika J. 2013: A klímaváltozás és a városi hösziget összefüggései. Természettudományi Közlöny 144(5): 197— 201.

Nagy I. 2008: Városökológia. Dialóg Campus Kiadó, Budapest-Pécs. p. 335.

Nowak, D J., Crane, D. E., Stevens, J. C. 2006: Air pollution removal by urban trees and shrubs in the United States. Urban Forestry & Urban Greening 4: 115-123. https://doi.org/10.1016/j.ufug.2006.01.007

Nowak, D. J., Heisler, G. M. 2010: Air Quality Effects of Urban Trees and Parks. National Recreation and Park Associaton 1: 45.

Oláh A. B. 2012a: A Városi beépítettség és a felszíntípusok hatása a kisugárzási hőmérsékletre. Doktori értekezés. Budapesti Corvinus Egyetem, Tájépítészeti Kar, Kert- és Szabadtervezési Tanszék, Budapest, p. 146.

Oláh A. B. 2012b: Városi hősziget mérséklése tájépítészeti eszközökkel. 4D Tájépítészeti és Kertművészeti folyóirat Különszám: 163-174.

Ottelé, M., van Bohemen, H.D., Fraaij, A. L. A. 2010: Quantifying the deposition of particulate matter on climber vegetation on living walls. Ecological Engineering 36: 154—162. https://doi.org/10.1016/j.ecoleng.2009.02.007

Perini, K., Ottelé, M.; Giulini, S.; Magliocco, A.; Roccotiello, E. 2017: Quantification of fine dust deposition on different plant species in a vertical greening system. Ecological Engineering 100: 268-276. https://doi.org/10.1016/j.ecoleng.2016.12.032

Poddar, S., Yoon Park, D., Chang, S. 2017: Simulation Based Analysis on the Energy Conservation Effect of Green Wall Installation for Different Building Types in a Campus. Energy Procedia 111: 226-234. https://doi.org/10.1016/j.egypro.2017.03.024

Patocskai M., Győrfi T. 2013: Lakossági üvegházgáz kibocsátások és semlegesítésének lehetőségei. Tájökológiai Lapok 11(2): 341-350.

Sepsi P., Sárközi E., Hrotkó K., Kardos L. 2015: Monitoring of air pollution in Budapest, Hungary using tree leaf samples - preliminary results. AgroLife Scientific Journal 4(1): 161-164.

Szabó B. (2015): A városi zöldfelületek hatása a város klímájára. Szakdolgozat. Eötvös Lóránd Tudományegyetem, Természettudományi Kar, Meteorológiai Tanszék, Budapest, p. 43.

Tamási A., Dobszay G. 2015: Requirements for Designing Living Wall Systems - Analysing System Studies on Hungarian Projects. Periodica Polytechnica Architecture 46: 78-87. https://doi.org/10.3311/PPar.8337

Vince T., Szabó Gy. 2009: Beregszász légszennyezettségének jellemzése a falevelekre rakódott por vizsgálata alapján. In: Kiss T. (szerk.): Természetföldrajzi folyamatok és formák. Geográfus Doktoranduszok IX. Országos Konferenciájának Természetfoldrajzos Tanulmányai. Szegedi Tudományegyetem Természeti Földrajzi és Geoinformatikai Tanszék, Szeged.

Wilkinson, S., Castiglia Feitosa, R., Tsuyoshi Kaga, L, Hachmann de Franceschi, I. 2017: Evaluating the Thermal Performance of Retrofitted Lightweight Green Roofs and Walls in Sydney and Rio de Janeiro. Procedia Engineering 180: 231—240. https://doi.org/10.1016/j.proeng.2017.04.182

httpl: https://forbes.hu/legyel-jobb/zoldhomlokzatokkal-kuzdenek-a-nyari-hoseg-ellen-becsben/ [2019. június 5.]

http2: www.greenwall.pro [2019. június 5.]

http3: www.budapest.hu [2019. június 5.]

Published

2019-12-12

Issue

Section

Articles

How to Cite

Assessment of design suitability and limiting factors of green facade systems in Budapest. (2019). JOURNAL OF LANDSCAPE ECOLOGY | TÁJÖKÖLÓGIAI LAPOK , 17(2), 255-263. https://doi.org/10.56617/tl.3521

Similar Articles

11-20 of 38

You may also start an advanced similarity search for this article.