Comparative Analysis of the Environmental Load of Natural Refrigerant (R290)

Szerzők

  • Houria Bouzghiba Hungarian University of Agriculture and Life Science, Doctoral School of Enviromental Science
  • Géczi Gábor Hungarian University of Agriculture and Life Sciences, Institute of Environmental Science

DOI:

https://doi.org/10.33038/jcegi.3506

Kulcsszavak:

ASHP, COP, refrigerant, R290, enviromental load

Absztrakt

Due to the detrimental environmental consequences of synthetic refrigerants, natural refrigerants have gained renewed interest as alternative refrigerants for a variety of applications due to their minimal ozone depletion potential (ODP) and insignificant global warming potential (GWP). This study compares the performance characteristics of R32-based Air Source Heat Pump (ASHP) to those of R290 and R410A refrigerants. In this study, analyses of the cooling effect, heat output, compressor work input, and coefficient of performance (COP) for various refrigerants will be undertaken. Additionally, the environmental consequences of R32, R410A, and R290 are discussed. The results indicate that R290 is the most efficient refrigerant in terms of performance coefficient, followed by R410A and R32. Considering environmental protection aspects, R290 is a favorable substitute medium.

Szerző életrajzok

  • Houria Bouzghiba, Hungarian University of Agriculture and Life Science, Doctoral School of Enviromental Science

    Houria Bouzghiba
    PhD Student
    Doctoral School of Enviromental Science, Hungarian University of Agriculture and Life Science,
    H-2100 Gödöllő, Páter Károly str. 1.
    bouzghiba.houria@phd.uni-mate.hu

  • Géczi Gábor, Hungarian University of Agriculture and Life Sciences, Institute of Environmental Science

    Dr. Gábor Géczi PhD
    associate professor
    Institute of Environmental Science, Hungarian University of Agriculture and Life Sciences,
    H-2100 Gödöllő, Páter Károly str. 1.
    geczi.gabor@uni-mate.hu

Hivatkozások

ABAS, N. – KALAIR, A.R. – KHAN, N. – HAIDER, A. – SALEEM, Z. – SALEEM, M.S. (2018): Natural and synthetic refrigerants, global warming: a review. Renew Sustain Energy Rev, 90, 557–569. DOI: https://doi.org/10.1016/j.rser.2018.03.099

BS4434 (1995): Specification for Safety and Environmental Aspects in the Design, Construction and Installation of Refrigeration Appliances and Systems, BSI Standards, London

CALM, J.M. (2007): The next generation of refrigerants – Historical review, considerations, and outlook. International Journal of Refrigeration, 31(7), 1123–1133. DOI: https://doi.org/10.1016/j.ijrefrig.2008.01.013

DALKILIC, A.S. – WONGWISES, S. (2010): A performance comparison of vapour-compression refrigeration system using various alternative refrigerants. International Communications in Heat and Mass Transfer, 37(9), 1340–1349. DOI: https://doi.org/10.1016/j.icheatmasstransfer.2010.07.006

HALIMIC, E. – ROSS, D. – AGNEW, B. – ANDERSON, A. – POTTS, I. (2003): A comparison of the operating performance of alternative refrigerants. Applied Thermal Engineering, 23(12), 1441–1451. DOI: https://doi.org/10.1016/S1359-4311(03)00081-4

HERMANUCZ, P. – BARÓTFI, I. – GÉCZI, G. (2018): Environmental and healthcare risks of refrigerants. Mechanical Engineering Letters, 17, 28–34.

JAMES, R.W. – MISSENDEN, J.F. (1992): The use of propane in domestic refrigerators. International Journal of Refrigeration, 15(2), 95–100. DOI: https://doi.org/10.1016/0140-7007(92)90033-Q

KEEBLER, J. (1993): Cold Fact: AC gas Danger. Automotive News, 45p.

MESSINO, A. – PANNO, D. (2012): Performance evaulation of cascade refrigeration systems using different refrigerants. International Journal of Air-Conditioning and Refrigeration, 20(3). DOI: https://doi.org/10.1142/S2010132512500101

OLESEN, B.W. – PARSONS, K.C. (2002): Introduction to thermal comfort standards and to the proposed new version of EN ISO 7730. Energy and Buildings, 34(6), 537–548. DOI: https://doi.org/10.1016/S0378-7788(02)00004-X

RITTER, T.J. (1996): Flamability-hydrocarbon refrigerants. Proceedings of the Institute of Refrigeration Conference, London 1996.11.21.

RICHARDS, R.G. – SHANKLAND, I.R. (1992): Flammability of alternative refrigerants. ASHRE Journal, 34(4), 22–24.

VIDAL, J. (1992): The Big Chill. The Guardian (November 19, 1992), p.2.

Letöltések

Megjelent

2022-12-13

Hogyan kell idézni

Comparative Analysis of the Environmental Load of Natural Refrigerant (R290). (2022). Journal of Central European Green Innovation, 10(Suppl 1), 135-142. https://doi.org/10.33038/jcegi.3506